Q-Flap RX™

Effectively decoupled.

REMBE® Q-Flap RX™

Decoupling of raw gas lines to filters + separators.

In the event of an explosion, the Q-Flap RX™ explosion isolation flap valve effectively isolates plant components in almost all industrial sectors. In order to meet the highly diverse requirements for the individual industries, the Q-Flap RX™ product range offers three different design versions. The nominal pipe sizes up to DN 710 feature an inspection flap, and the larger nominal pipe sizes have a modular design. This ensures that a maintenance and servicing of any pipe size can be carried out easily.
Application
The Q-Flap RX™ is also perfectly suited, for the aspiration lines of filtering dust collectors, and for the suction intake lines of mills. The nominal pipe sizes up to DN 400 are primarily used for decentralised extraction systems in the pharmaceutical and chemical industries, whereas nominal pipe sizes between DN 450 and DN 710 are also used for centralised dust extractors in the grain and food industry. Nominal pipe sizes from DN 800 to DN 1000 are used in the wood and heavy industry.
REMBE® Q-Flap RX™ with Accessoires

Spare parts set

Advantages
  • Quick maintenance without the need for a complete dismantling of the device, simply by completely opening the inspection flap on pipe sizes up to DN 710.
  • Optionally: longer maintenance intervals by integrating a supervision function.
  • No boundary’s: Q-Flap RX™ available up to DN1000. More sizes available on request.
Mechanism
When the system is shut down, the valve blade rests in an inclined position. During normal operation, the explosion isolation flap valve is kept open by the air flow of the system. In the event of an explosion, the valve blade is closed by the pressure wave of the explosion.
Technical data
Product parameters
Type
With swith/without switch (please indicate on order)**, Steel/stainless steel (please indicate on order)
Certification
According to EU guideline 2014/34/EU (ATEX 114) and NFPA 69***
Mounting position*
Horizontal, suction side (fan after flap "pull flow")
Operating air flow velocity
12 to 35 m/s
Temperaturen*
Ambient temperature: -20°C up to +80°C (without switch max. +100°C), Process temperature: +1° C up to +80 °C (without switch max. +100 °C)
Material
Housing: steel/stainless steel**, flap blade: stainless steel, sealing: EPDM/silicone, PTFE
Connection flange
DIN 24154 part 2
Raw gas dust concentration
max. 100 g/m³
* Our specialists will gladly consult you personally in case of deviating operating conditions.
** On request.
*** Optional.
Applications + Industries
  • animal feed productions
  • aspiration plants
  • brewery
  • chemical- petrochemical
  • filters
  • food
  • food production
  • mills and grinding plants
  • mixers
  • recycling
  • wood processing

Certifications

Certified in
accordance with

EN 16447
ATEX EC type examination certificate no. GEX 19 ATEX 1004X (DN 140 to 1000)

ATEX EC type
examination certificate no. GEX 19 ATEX 1004X (DN 140 to 1000)

Meets the requirements of NFPA 69

Meets the requirements of NFPA 68

The Q-Flap RX™ ensures reliable explosion isolation to protect your plant and minimize the effects of an explosion.

  • Click and drag image to view.
  • Scan the QR code with your iOS camera* to see an AR preview of the product.
    Q Flap RX AR Viewer Ru
    The dimensions shown may differ from those of the actual product.
    * Requires iOS 13, iPadOS 13, ARCore 1.9 or higher.
  • REMBE is your specialist in the field of explosion safety and pressure relief and offers holistic safety concepts for plants of all kinds in a wide range of industries. All products are manufactured in Germany and meet the requirements of national and international regulations. In this video, an experienced REMBE employee explains in practical terms how you can unlock the Q-Flap RX yourself on site with a few simple steps after it has been triggered. As well as the explanations in this video, the operating instructions of the products must always be observed. You can find more information about the Q-Flap RX at https://www.rembe.de/produkte/explo... or contact us directly at hello@rembe.de. Chapters: 00:00 Introduction 00:25 Remove the bolts in the housing cover 00:38 Remove dust protection 01:08 Loosen the locking mechanism 01:25 Check valve blade 01:39 Tighten the locking mechanism and close the housing 02:36 Overview
    REMBE is your specialist in the field of explosion safety and pressure relief and offers holistic safety concepts for plants of all kinds in a wide range of industries. All products are manufactured in Germany and meet the requirements of national and international regulations. In this video, an experienced REMBE employee explains in practical terms how you can unlock the Q-Flap RX yourself on site with a few simple steps after it has been triggered. As well as the explanations in this video, the operating instructions of the products must always be observed. You can find more information about the Q-Flap RX at https://www.rembe.de/produkte/explo... or contact us directly at hello@rembe.de. Chapters: 00:00 Introduction 00:28 Remove the bolts in the housing cover 00:45 Remove dust protection 00:58 Loosen the locking mechanism 01:15 Check valve blade 01:24 Tighten the locking mechanism and close the housing cover 02:23 Overview
    REMBE is your specialist in the field of explosion safety and pressure relief and offers holistic safety concepts for plants of all kinds in a wide range of industries. All products are manufactured in Germany and meet the requirements of national and international regulations. This video explains how the maintenance of the REDEX Slide is carried out by the service specialists from REMBE Advanced Services + Solutions GmbH. Using a test setup, the maintenance of the slide valve up to a size of DN 400 is shown realistically. The maintenance of the REDEX Slide may only be carried out by the REMBE Advanced Services + Solutions GmbH team as a qualified person. You can find more information about the REDEX Slide at https://www.rembe.com/products/expl... contact us directly at hello@rembe.de. Chapters: 00:00 Introduction 00:40 Open the housing cover 00:47 Inspection of the valve blade 01:00 Inspection of the locking mechanism of the valve blade 01:24 Unlocking the flap 02:10 Function test 02:21 Resistance check between valve blade and housing 02:40 Closing of the housing cover and inspection of the installation
Your contact person
I will be happy to advise you about the most suitable Protection systems for your plant. Individually, in detail and taking all relevant parameters into ­account.
Julia Groß | Assistant to Chief Business Development Officer
Consulting. Engineering. Products. Service.
REMBE® GmbH Safety+Control
© REMBE® GmbH Safety+Control